400-021-5850
Tmall store
WeChat
WeChat
search menu
Close
Close
contact

SYD-265E Asphalt Kinematic Viscosity Tester

Product information: This instrument is designed and manufactured according to the requirements specified in the industry standard T0619 "Asphalt Kinematic Viscosity Test (Capillary...

Online Message
SYD-265E Asphalt Kinematic Viscosity Tester

SYD-265E Asphalt Kinematic Viscosity Tester

Close

Product Overview

Product Information

This instrument is designed and manufactured according to the requirements specified in the industry standard T0619 "Asphalt Kinematic Viscosity Test (Capillary Method)" of the People's Republic of China. It is used to measure the kinematic viscosity of asphalt samples at specified temperatures in accordance with the requirements specified in T0619 standard. The experimental results of this instrument comply with the requirements of JTG 3410-2025 "Test Regulations for Asphalt and Asphalt Mixtures in Highway Engineering" issued by the Ministry of Transport of the People's Republic of China.

Product Features:

1. High temperature constant temperature bath: The inner layer adopts a hard glass cylinder with a diameter of Ø 300x300mm, which can withstand a temperature of 180 degrees. There are four holes on the bathtub cover, which are used to place capillary viscometer clips and rubber wood covers respectively. There are three adjustment screws installed on the clamp to adjust the verticality of the capillary viscometer.

2. The lighting adopts 220V 16W2D fluorescent lamp, which provides a guarantee for clear observation of the reading of the capillary viscosity meter.

3. Temperature controller: (1) Temperature sensor: Industrial platinum resistance, with a division number of Pt100.

(2) Temperature controller: Intelligent temperature controller with PID self-tuning and four position dual LED window indication function, fast temperature control, fast response, small overshoot, and temperature control accuracy of ± 0.1 ℃.

(3) Heating system: using 1800W heating tubes for heating. When the instrument starts working, it heats up at full power; Enter slow heating near the set temperature point to ensure stable bath temperature.

4. Mixing system: The electric mixer is a single-phase asynchronous motor. The electric shaft and mixing shaft are isolated by epoxy rods, which will not affect the normal operation of the motor.

Main technical parameters:

1. Working power supply: AC220V ± 10%, 50Hz

2. Heating power of bath solution: 1850w (temperature controlled heating)

3. Bath solution usage temperature: room temperature~150.0 ℃

4. Temperature control accuracy of water bath: ± 0.1 ℃

5. Mercury thermometer: with a division of 0.1 ℃ and a temperature measurement range of 100-150 ℃

6. Water bath capacity: 20L

7. Sample quantity: 4 capillary tubes inserted simultaneously

8. Mixing motor: power 6w, speed 1200r/min

9. Environmental temperature: -10 ℃~+35 ℃

10. Relative humidity:

11. Temperature sensor: Industrial platinum resistance, with a division number of Pt100

12. Power consumption of the whole machine: not exceeding 1850W

13. Capillary viscometer: A set of seven Kanfen counter current capillary viscometers, with models of 200, 300, 350, 400, 450, 500, and 600 (i.e. R tube inner diameters of 1.02, 1.26, 1.48188, 2.20, 3.10, and 4.00 millimeters, respectively)


Related Downloads

Instruction Manual
预览 下载
Program Download
下载
 
logo
©2025-2026 All Rights Bejing Spaceflight Technology Instrument Co.,Ltd. Copyright

Tel 400-021-5850
Email Email:8B2, 7th Floor, No. 6 Nanxinyuan West Road, Chaoyang District, Beijing
QR code

WeChat