SYD-0620 Asphalt Dynamic Viscosity Tester

Product information: This instrument complies with the industry standard JTG3410-2025 "Test Code for Asphalt and Asphalt Mixtures in Highway Engineering" of the People's Republic of...

Online Message
SYD-0620 Asphalt Dynamic Viscosity Tester

SYD-0620 Asphalt Dynamic Viscosity Tester

Close

Product Overview

Product Information

This instrument is designed and manufactured in accordance with the requirements of T0620-2000 "Asphalt Dynamic Viscometer (Vacuum Reduced Pressure Capillary Method)" in the industry standard JTG3410-2025 "Test Code for Asphalt and Asphalt Mixtures in Highway Engineering" and the industry standard SH/0557 "Petroleum Asphalt Viscosity Determination Method (Vacuum Capillary Method)" of the People's Republic of China. This instrument is suitable for measuring the dynamic viscosity of petroleum asphalt using a vacuum depressurization capillary viscometer. Unless otherwise specified, the test temperature is 60 ℃ and the vacuum degree is 300mmHg. This instrument is also suitable for other substances using vacuum capillary method, with a test temperature of 60 ℃, a vacuum degree of 300mmHg (-40Kpa), and a viscosity of 0.0036-20000Pa. s. The vacuum degree and test temperature of this instrument can be set separately, and can also be applied to other non-standard tests.

Product Features:

1. Automatic temperature and vacuum control with high precision.

2. High resolution 7-inch Chinese LCD screen display, touch operation, temperature and vacuum can be calibrated through button operation, and calibration data can be automatically saved.

3. Capillary parameters can be pre-set and stored. The experimental time and test results are automatically calculated and historical experimental data can be saved.

4. Equipped with a high-precision timer, controlled by manual buttons.

5. It has the function of storing and printing calculation results.

6. Quick detachable glass cylinder structure design.

Main technical parameters:

1. Working power supply: AC 220V ± 10%, 50HZ/60HZ

2. Environmental temperature: 5-45 ℃

3. Relative humidity:

4. Temperature control range: ambient temperature -99.9 ℃

5. Temperature control accuracy: 0.1 ℃

6. Applicable pressure range: 0- (-50KPa) can be set

7. Timing range: 0-99.9S

8. Timing accuracy:

9. Measurement range: 4.2-580000Pa. s

10. Quantity of measurable samples: 3 (1 spare)

11. Dimensions: 490 * 430 * 655mm

12. Net weight: 30kg

13. Packaging size: 555 * 475 * 840mm

14. Gross weight: 40kg